6482 - CrossLink-NX: Does LIFCL-40/LIFCL-17 CSFBGA121 has external VREF pin for ADC?
6482 - CrossLink-NX: Does LIFCL-40/LIFCL-17 CSFBGA121 has external VREF pin for ADC?
Solution:
Based on Appendix B of FPGA-TN-02129 (ADC User Guide for Nexus Platform), package CSFBGA121 does not support external VREF for both LIFCL-40 and LIFCL-17.
Understanding ADC Calibration and Accuracy When working with precision analog-to-digital conversion (ADC) systems, especially in low-voltage applications, achieving accurate and repeatable results is critical. Customers often encounter discrepancies ...
Description:This article explains the reason ADC clock-in cannot be driven using an oscillator output in CertusPro-NX. Solution:In CertusPro-NX., the ADC clock input is hard-wired on the fabric to the 4th secondary output (CLKOS4) of the Lower Right ...
Users have a couple of options for their design to use the CrossLink-NX evaluation board: 1. Use an external clock from a different clock pin: Instead of using the onboard oscillator, users can connect one of the other PCLK pins as input to the FPGA ...