Users have a couple of options for their design to use the CrossLink-NX evaluation board: 1. Use an external clock from a different clock pin: Instead of using the onboard oscillator, users can connect one of the other PCLK pins as input to the FPGA ...
Solution: Depending on what software you are using, (Radiang Software or iCEcube2), you can change the configuration oscillator clock frequency using these steps. Radiant Software: Go to Project > Active Stratefy > Bitstream Settings > Oscillator ...
Yes, the internal oscillator can be used as a clock source for the PLL. There are specific primitives for this (SB_PLL40_CORE and SB_PLL40_CORE), which will automatically be instantiated when we use the included PLL module generator from iCEcube2 ...
When the PLL is in power down (default when it is not used), the current to PLL is turned off, and the VCO and Charge Pump is not running. After programming completes, there is a dedicated global bit to disable the oscillator. Oscillator is turned ...
Description:This article explains the reason ADC clock-in cannot be driven using an oscillator output in CertusPro-NX. Solution:In CertusPro-NX., the ADC clock input is hard-wired on the fabric to the 4th secondary output (CLKOS4) of the Lower Right ...