It is recommended to use the Clone Implementation option in Radiant. From the File List tab, right-click on the implementation name (ex. impl1) then click "Clone Implementation". This will copy all the settings from the original implementation. From ...
In both ispLEVER and Lattice Diamond tools, user can generate the timing using the static timing analysis tool after map, and before place and route. The static timing analyzer (TRCE) will generate timing using estimated models, as well as the fanout ...
It is not recommended to change the default speed grade settings for both the Place & Route (PAR) Design and Place & Route Timing Analysis. DEFAULT VALUES: The default values (especially for HOLD) are for worst case timing calculations. For PAR ...
Description: The user can alter the sysConfig settings via bitstream generation command, this can be done using the following methods: Note: In this example, BACKGROUND_RECONFIG was used. Solution: (1) Through Bitstream Strategy Settings Command ...
Description: You can change the post-route preference file (.prf) by adding "INDUSTRIAL;" and "TEMPERATURE 85C;". Also at the same time the trace options can be updated in ispLEVER's Tools-> Trace Options or Lattice Diamond's Strategies->Place & ...