Kindly refer below to the exception priority:
1. set_false_path
2. set_max_delay or set_min_delay
3. set_multicycle_path

A couple of notes:
1. set_max_skew applies to the timing path together with exception constraint that takes priority.
2. set_clock_groups although not considered a timing exception takes the higher priority than the timing exceptions.