Why does the Radiant Place & Route “Pinout by Pin Number” report list MachXO4 pads that are not in the package pinout?

Why does the Radiant Place & Route “Pinout by Pin Number” report list MachXO4 pads that are not in the package pinout?

Problem / Question

In the Radiant Place & Route report, the “Pinout by Pin Number” section lists entries such as PB3A marked “unused, PULL:DOWN”. These entries do not appear in the published pinout table or the package migration table for the selected MachXO4 package. Are these extra I/O pins that can be used in a design?


Root Cause / Explanation

No. These entries are I/O pads on the silicon die that are not connected (not “bonded”) to any pin in the selected package. They are not user-accessible I/O.

  • The “Pinout by Pin Number” section is built from the device’s list of I/O cells, which comes from the die, not from the selected package.
  • A pad can be used only when the package connects it to a package pin. Which pins are usable therefore depends on the package, but the list of pads does not.
  • Pads that are not bonded are still listed with their default state, so they appear as “unused, PULL:DOWN”.
  • In the package pinout table, these pads show a dash (-) in the column for that package.

Resolution / Recommendation

No design change is needed. These entries do not affect the design or the pins already in use. To check which pins are available in the selected package:

  1. Radiant Device Constraint Editor: After synthesis, open the package view. It is specific to the ordering part number shown in the view header. Hovering over a pin shows both the Pin name (the package pin) and the Pad name (the die pad). Pads that are not bonded do not appear as pins in this view.

  1. Lattice website: Go to Products > FPGA & CPLD > MachXO4 > Documentation > Quick Reference > Pin & Package. Check the pinout table for the device and the migration table for the package.

Do not use the Place & Route report to decide which pins are available.

Technical Notes

  • If a port is constrained to a pad that is not bonded, the Map stage rejects it with error 71003010, which states that the port is assigned to a nonexistent pin. For example:
  ldc_set_location -site {PB3A} [get_ports {d[0]}]

  • Radiant 2026.1 has no documented option to hide these entries in the report or label them as non-bonded.