Problem / Question
On the Certus-NX sysCLOCK PLL, PHASESEL[2:0] selects which output receives dynamic phase adjustment. Codes 000 to 101 map to CLKOP through CLKOS5. For example, CLKOS5 is not configured in the PLL instance, but PHASESEL is set to 101 (CLKOS5) and PHASESTEP is pulsed. It is unclear how the PLL responds.
Root Cause / Explanation
The following general behavior was confirmed:
- PHASESEL[2:0] works like a multiplexer. Each PHASESTEP pulse goes only to the selected output.
- Outputs that are not selected keep their current phase. That phase is the static setting plus any steps applied to them earlier.
- Selecting an output with PHASESEL does not shift its phase by itself. A shift happens only when PHASESTEP is pulsed.
Resolution / Recommendation
- Treat a phase step on an unconfigured output as unsupported.
- Pulse PHASESTEP only when PHASESEL selects an output that is configured in the PLL instance.
- Add a check in user logic that blocks PHASESTEP when PHASESEL points to an unused output.
- Hold PHASESEL and PHASEDIR stable for at least 5 ns before the falling edge of PHASESTEP.
Technical Notes
- Only one output can be phase-shifted at a time.