Reference Clock Frequency Fixed to 60 MHz in IP GUI of the MIPI CSI/DSI IP

Reference Clock Frequency Fixed to 60 MHz in IP GUI of the MIPI CSI/DSI IP

Issue Description: 
In MIPI CSI/DSI IP v4.2.0 (Soft D-PHY), an IP GUI bug has been identified that causes the Reference Clock Frequency setting in the GUI to be fixed at 60 MHz. As a result, users cannot generate the IP with a different Reference Clock frequency through the GUI, even if the target design requires a non-60 MHz Reference Clock.

Affected Device/s: 
All devices supporting Soft D-PHY

Affected IP/s:
MIPI CSI/DSI v4.2.0

Issue Resolution / Workaround / Mitigation: 
For designs requiring a Reference Clock frequency greater than 60 MHz, users may drive ref_clk_i with the desired target frequency. If required, update the corresponding top-level PDC constraints in the system design to reflect the actual Reference Clock frequency being used. This workaround allows the IP to operate with the intended Reference Clock frequency despite the GUI limitation.