This article provides guidance for selecting the reference clock source for the CertusPro-NX MPCS IP core. The correct reference clock source depends on the number of lanes configured in the design.
The specification states the following requirement for higher lane-count configurations:
For applications with more than four lanes, the reference clock source from sd_ext_0/1_refclk_i must be used.Two configuration scenarios apply, as summarized in the tables below.
| Reference Clock Source | Status |
|---|---|
sdq_refclkp_q0/1_i | Recommended |
sd_ext_0_refclk_i | Recommended |
sd_ext_1_refclk_i | Recommended |
pll_0_refclk_i | Not Recommended |
pll_1_refclk_i | Not Recommended |
sd_pll_refclk_i | Prohibited (test purposes only) |
| Reference Clock Source | Status |
|---|---|
sd_ext_0_refclk_i | Recommended |
sd_ext_1_refclk_i | Recommended |
sdq_refclkp_q0/1_i | Prohibited |
pll_0_refclk_i | Prohibited |
pll_1_refclk_i | Prohibited |
sd_pll_refclk_i | Prohibited |
| Color / Label | Meaning |
|---|---|
| Recommended | Preferred reference clock source for the given lane configuration |
| Not Recommended | Functional but not advised for production designs |
| Prohibited | Must not be used for the given lane configuration; the "test purposes only" designation under Table A applies to bench validation, not production use |
sdq_refclkp_q0/1_i, sd_ext_0_refclk_i, or sd_ext_1_refclk_i as the reference clock source.sd_ext_0_refclk_i or sd_ext_1_refclk_i, in accordance with FPGA-IPUG-02118-2.0, Section 2.2.3.