Radiant 2023.2 and above: Why does the command "-exp WARNING_ON_PCLKPLC1=1" on PAR does not work on Radiant 2023.2?

Radiant 2023.2 and above: Why does the command "-exp WARNING_ON_PCLKPLC1=1" on PAR does not work on Radiant 2023.2?

Description:
In Radiant 2023.1 and lower versions, the command "-exp WARNING_ON_PCLKPLC1=1" works to bypass the DRC error when assigning clock ports on pins that are not PCLK. Due to some changes with the DRC of Radiant 2023.2, it also affected the MAP phase process when checking PCLK assignments. This means that even if adding the bypass command on PAR cmd options, it will still get blocked by the MAP phase.

Solution:
As a workaround to enable the bypass command, please try setting the bypass command on your machine's environment variable. See below example: