<div>Radiant: What type of clocks do the Clock Port column of the I/O Timing Analysis Report refer to?</div>

<div>Radiant: What type of clocks do the Clock Port column of the I/O Timing Analysis Report refer to?</div>

For I/O timing analysis, the "Clock Port" column/field could refer to the following depending on the destination clock:
1. Internal oscillator clock: If the destination clock is directly from the internal oscillator, or if the destination clock is from a PLL clock output sourced from the internal oscillator.
2. External clock port: If the destination clock is directly from an external clock port or if the destination clock is from a PLL clock output source from an external clock port.

In this example case, since the destination clock of the path (based on the set_false_path constraint) is from a PLL clock output source from an external clock port, then the external clock port (CLK_25MHz) will be on the "Clock Port" column of the I/O timing analysis report.

See timing report section for the timing path: