800 - Power Manager II: What is the maximum junction temperature Tj for the POWR1220AT8 device?

800 - Power Manager II: What is the maximum junction temperature Tj for the POWR1220AT8 device?

The absolute maximum junction temperature of the PAC-POWR1208P1 is at 130°C. Operation at or above this temperature will permanently degrade performance or permanently damage the device. In addition, operation outside of the recommended operation temperature (-40°C to +85°C) will result in inferior performance, such as VMON trip point errors, timing errors, and HVOUT failures.