7496 - Radiant: ERROR <1081326> - Bitstream cannot be generated, either because this device does not support IP Evaluation Mode or the Bitstream Strategy Setting for IP Evaluation Mode is set to False

7496 - Radiant: ERROR <1081326> - Bitstream cannot be generated, either because this device does not support IP Evaluation Mode or the Bitstream Strategy Setting for IP Evaluation Mode is set to False

Description:
When generating a bitstream in Radiant, the error below might occur:

ERROR <1081326> - Bitstream cannot be generated, either because this device does not support IP Evaluation Mode or the Bitstream Strategy Setting for IP Evaluation Mode is set to False

This error indicates that the design may contain an IP and no IP license is found and/or the FPGA device used needs a subscription license and the "IP Evaluation" Strategy Setting in the design is not enabled.

Solution:
To eliminate the error and proceed with bitstream generation, there are two options:

1. Enable the "IP Evaluation" Strategy setting in the design but the bitstream generated will be limited to a maximum of 4 hours of being functional before the device reset itself.
2. The user procures either an IP license for the IP used on their design and/or a subscription license for the device used.