6523 - Certus-NX: Can LVDS IOs be used on banks 6 & 7 and what limitations are there? Are inputs to be LVDS25E or does that just apply to outputs? For inputs, on banks 6 & 7, are the 100 termination resistors available?
Bank 3, 4, and 5 are the High Speed Banks that support True LVDS. For Bank 6 and 7, although pins can operate through differential pair, its speed is limited to LVCMOS (Input and Output) or LVDS25E (output).
Single ended termination with programmable 40/50/60/75 Ω resistor is supported on all banks, but only banks 3, 4 and 5 support on-chip 100Ω dynamic differential input termination.