5760 - [Platform Manager II]: In the Hot Swap sheet in Platform Designer, when Rs is set to 10 milliohms, the Fast Shutdown Limit can reach 20 A with max. However, in the Current sheet, when Rs is also set to 10 milliohms, the Fast Trip Point can reach 50
1. Fast Shutdown limit is also related to the Imax setting.
2. Fast shutdown Limit can also go up to 50A if Imax is set to 50A and above even with the same 10millohm resistor value.
3. Fast Shut Down Limit uses the IMON_F input which allows a propagation delay of about 1µs because it has a direct connection to the OCB (Output Control Block). In checking the IMON_P and IMON_N, it has additional stages that allow additional features but introduce propagation delays. The outputs of the current monitors are available for any user logic in addition to the Hot Swap logic.