2310 - PAC-Designer: Why does my POWR1014A design fail to compile but not give an error message?
If your Power Manager II design fails to compile and gives no error message it could be due to the use of periods or spaces in the project file name or the path name. Usually the failure message is produced immediately after starting the compile process for these errors.
Sometimes you may also see the following messages in the error window:
AHDL2BLF; ABEL-HDL Processor
PAC-Designer 6.30 Copyright(C), 1992-2005, Lattice Semiconductor Corporation. All rights reserved
Portions Copyright(c), 1992-1999, Vantis Corporation
Portions Copyright(C), 1993-1998, Data I/O Corporation
Portions Copyright(C), 1997-1998, MINC Washington Corporation
Portions Copyright(C), Alan Phillips, Lancaster University Computer Centre 1992-1998
Warning 1211: Generate NAF file failed, please compile design to get detailed error information.
Strange results can be caused by using periods or spaces in the project file name or the path name. I recommend that you do not use any periods or spaces in the file name or path name to the file. You can include underscores in the file/path name if you want to.